Quest Diagnostics Certified Lab Interface
Does your EHR speak HL7 ...
Fully integrated lab orders and results interface and workflow that supports ask-on-entry, automatic send, and automatic results checking. Results are auto-matched to patients, and as MAs review the result queue they typically issue a lab review task to providers for patients with abnormal results.
From Client:MSH|^~\&|BRIO|TE015308|PSC|SO|20111209||ORM^O01||P|2.3||||||
PID|1|121||121|ZCC^TEST^||19900101^021^11^08|F||C|111 WOOD ST^^IRVINE^CA^92614||9491231234||ENGLISH|||04992875^^^P|123456666||||||||||
ZCC|P|||||||||||||||||||||||||||||||||||||||||||||||
GT1|1||ZCC^TEST^||111 WOOD ST^^IRVINE^CA^92614|9491231234|||||1|||||||||||||||||||||||||||||||||||||||||||
DG1|1|I9|250.00|DIABETES; NON-INSULIN DEP||||||||||||||||
ZCI||||Y||||||||||||||||
ORC|NW|BUN554||||||||||1538230453^KILDARE^HENRY^^^^^N|
OBR|1|BUN554||001032^GLUCOSE, SERUM^L|||201112090322||||N||THIS IS RELEVANT CLINICAL INFORMATION|||1538230453^KILDARE^HENRY^^^^^N||||||||||||||||||||||||||
To COR:ReqnSubmitTmstp: 12/09/2011 06:28:24 PM
RequisitionNum: BUN554
PatientFirstNm: TEST
PatientLastNm: ZCC
PatientBirthDt: 01/01/1990 12:00:00 AM
PatientId: 121
AccountNum: 04992875
PhysicianFirstNm: HENRY
PhysicianLastNm: KILDARE
OrderedTests: 001032
CreateUserid: TESTLES9
Transformed HL7 (to Quest):MSH|^~\&|BRIO|TESTLES9|PSC|SO|20111209000000||ORM||P|2.2
PID|1|121||121|ZCC^TEST||19900101^021^11^08|F||C|111 WOOD ST^^IRVINE^CA^92614||9491231234|||||04992875^^^04|123456666
ZCC|P
GT1|1||ZCC^TEST||111 WOOD ST^^IRVINE^CA^92614|9491231234|||||1
DG1|1|I9|250.00^^I9
ZCI||||Y
ORC|NW|||||||||||^KILDARE^HENRY^^^^^N^^1538230453
OBR|1|BUN554||001032^GLUCOSE, SERUM^L|||||||N||^THIS IS RELEVANT CLINICAL INFORMATION
ZTR|1538230453|BUN554
LabCorp Certified Lab Interface
ICD-10 Certified ...
Fully integrated lab orders and results interface and workflow that supports ask-on-entry, automatic send, and automatic results import. Additionally, AXEIUM is ICD-10 certified with LabCorp.
As with all lab data, regardless of source, all lab information is stored as structured data, and reportable by LOINC code internally, and via referral on C-CDA formatted CCD.
Meditech Custom Lab Interface
Does your EHR accommodate special requests ...
If you have a captive lab, as is often the case with hospital-sponsored clinics, your lab orders and/or results can be integrated into AXEIUM to provide a standard review process.
For example, at the La Amistad clinic the lab results from the St. Joseph Hospital Meditech system are imported daily and reported in the same format as labs received from other sources, i.e., Quest Diagnostics, LabCorp and in-house.